Ticket Name: RTOS/TDA2: DCAN2 external loopback test mode stuck at Utils_dcanWaitForTxComplete()
Query Text:
Part Number: TDA2 Tool/software: TI-RTOS Hi, I have the same problem! It stuck at Utils_dcanWaitForTxComplete(). please help to give me some advisement Thanks~~
Responses:
Hi, Have you tried all the things suggested in above e2e thread? If yes and still facing same issue, can you take a dump of DCAN2 registers and DCAN2 message RAM? Thanks & Regards, Vivek Dhande. Texas Instruments (India) Pvt Ltd
Hi, I found the problem. Some default usecase would use the same pin and would modify pinmux after mine. Thanks~