Ticket Name: TDA2: DDR3 Routing Specifications
Query Text:
Part Number: TDA2 Referring to TDA2 data sheet, Table 8-52, are there typo errors in unit? Example, should the A1+A2 length in mil instead of ps? Or how to correlate the max 500ps to signal length?
Responses: