Ticket Name: TDA2: DDR3 Routing Specifications | |
Query Text: | |
Part Number: TDA2 Referring to TDA2 data sheet, Table 8-52, are there typo errors in unit? Example, should the A1+A2 length in mil instead of ps? Or how to correlate the max 500ps to signal length? | |
Responses: | |
Hi, The units ("ps") are correct. Determining the max signal length (in mils) will be dependent on the material of the PCB and whether the signals are routed as microstrip or stripline. Best regards, Kevin | |